132
Technical Data
• EPS (Off-grid) Output
Model
X3-Hybrid-
5.0-D
X3-Hybrid-
6.0-D
X3-Hybrid-
8.0-D
X3-Hybrid-
10.0-D
X3-Hybrid-
10.0K-D
X3-Hybrid-
12.0-D
X3-Hybrid-
12.0K-D
X3-Hybrid-
15.0-D
X3-Hybrid-
5.5-D LV
X3-Hybrid-
8.3-D LV
EPS(Off-grid)
rated power [VA]
5000 6000 8000 10000 12000 15000 5500 8300
EPS(Off-grid)
rated voltage
[a.c. V]
400/230 220/127
Frequency [ Hz] 50/60 50/60
EPS(Off-grid)
rated current
[a.c. A]
7.2 8.7 11.6 14.5 17.5 21.8 14.5 21.8
EPS(Off-grid)
peak power [VA]
12000,10s 12000,10s 18000,10s 18000,10s 22500,10s 22500,10s 9900,10s 12400,10s
Switching time
[ms]
< 10 ms
Total harmonic
distortion (THDv)
<
3%
• Generic Data
Model
X3-Hybrid-
5.0-D
X3-Hybrid-
6.0-D
X3-Hybrid-
8.0-D
X3-Hybrid-
10.0-D
X3-Hybrid-
10.0K-D
X3-Hybrid-
12.0-D
X3-Hybrid-
12.0K-D
X3-Hybrid-
15.0-D
X3-Hybrid-
5.5-D LV
X3-Hybrid-
8.3-D LV
Dimensions
(W/H/D)[mm]
503 * 503 * 199
Dimensions of
packing
(W/H/D)[mm]
560 * 625 * 322
Net weight [kg] 30±1 30±1 30±1 30±1 30±1 30±1 30±1 30±1
Gross weight * [kg] 34±1 34±1 34±1 34±1 34±1 34±1 34±1 34±1
Heat dissipation
treatment
Natural Cooling Smart Cooling
Natural
Cooling
Smart
Cooling
Noise
emission(typical)
[dB]
< 35 <45 < 40 <45
Storage
temperature range
[°C]
-40 to +70
Operating ambient
temperature range
[°C]
-35 to +60 (derating at 45)
Humidity [%] 4%-100% (condensing)
Altitude [m] < 3000
Ingress protection IP65
Protective class I
Cold standby
consumption
< 5W
Overvoltage
category
III (MAINS), II (PV, Battery)
Pollution degree III
Installation mode Wall-mounted
Inverter topology Non-isolated
Communication
interface
CT / Meter (optional), External control RS485, Pocket WiFi (Optional: Pocket Lan / 4G), DRM, USB
Upgrade, NTC (optional)