125
13 Decommissioning
13.1 Disassembling the Inverter
WARNING!
• Strictly follow the steps below to disassemble the inverter.
• Only use the dedicated removal tool delivered with the inverter to disassemble the PV
connector.
Step 1: Turn off the system by System ON/OFF on LCD screen.
Step 2: Disconnect the external AC breaker of the inverter.
Step 3: Turn the DC switch to OFF. For how to turn off lockable DC switch, see "9.4
Operation of Lockable DC Switch".
Figure 13-1 Turning off the DC switch
Step 4: Turn off the battery switch / button / breaker (if any). (See documents of battery)
Step 5: Disconnect the PV connectors: Insert the removal tool into the notch of PV
connectors and slightly pull out the connectors.
Figure 13-2 Disconnecting the PV connector