8
Product Overview
2.5.2 Application Schemes
Inverter
Grid
EPS
(off-grid)
L1
N
L3
L2
PE
L1
N
L3
L2
CT
Breaker Main breakerRCD
Breaker
RCD RCD
Breaker
Breaker
Load
Load
E-BAR
Grid
N-BAR for EPS loads N-BAR for loads
Distribution box
L1
L2
N
L3
Battery
BAT
-
+
Figure 2-6 Partial home backup for Europe
Inverter
Grid
EPS
(off-grid)
L1
N
L3
L2
PE
L1
N
L3
L2
CTCT
BreakerBreaker
Main breakerMain breaker
Breaker
RCD
Breaker
Load
E-BAR
Grid
N-BAR for EPS loads
Distribution box
L1
L2
N
L3
Battery
BAT
-
+
RCDRCD
Figure 2-7 Whole home backup for Europe