15.2.4 Settings for Adapter Box G2
a. Select Menu>Setting>Advance Setting>Modbus;
b. Select the AdapBox G2 and set the Baud Rate and corresponding Address. The
default Baud Rate is 9600.
=======Modbus=======
>Function Control
AdapBoxG2
=======Modbus=======
>Baud Rate
9600
=======Modbus=======
>AdapBoxG2 Addr:
96
NOTICE!
When two equipments need to be connected at the same time, the Baud rate of the
two equipments shall be set to the same.
c. Check the connection status.
=======Modbus=======
>AdapBox G2 COM STAT
Connected
NOTICE!
For specific wiring and setting procedures of Adapter Box G2, see Adapter Box G2
user manual.