9
Product Overview
⋯
Inverter
Grid
EPS
(off-grid)
L1
N
L3
L2
PE
L1
N
L3
L2
CT
Breaker Main breaker
Breaker
RCD RCD
Breaker
Breaker
Load
Load
E-BAR
Grid
N-BAR for EPS loads N-BAR for loads
Distribution box
L1
L2
N
L3
Battery
BAT
-
+
Figure 2-8 Partial home backup for Australia
Inverter
Grid
EPS
(off-grid)
L1
N
L3
L2
PE
L1
N
L3
L2
CTBreaker Main breaker
Breaker
RCD
Breaker
Load
E-BAR
Grid
N-BAR for EPS loads
Distribution box
L1
L2
N
L3
Battery
BAT
-
+
Figure 2-9 Whole home backup for Australia
NOTICE!
• Only qualified personnel can perform the wiring connection of the inverter.
• When power cuts suddenly, the inverter connects the N line of EPS (Off-grid) load
with the ground through relay, providing a fixed zero potential for EPS (Off-grid) load
and ensuring the safety of electricity use by users.