EasyManua.ls Logo

SolaX Power X3-Hybrid G4 Series - Page 20

SolaX Power X3-Hybrid G4 Series
182 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
Product Overview
Time period Inverter working status
Allowed discharging
period
PV is sufficient
(PV
load
battery
grid)
The power generated from PV prioritizes supplying the load.
Any excess power is then directed towards charging the
battery, and if there is still surplus electricity, it can be sold to
the grid. In the event that the local utility restricts the sale of
electricity to the grid, the Export Control value can be set on
the inverter. Please refer to "Setting Export Control".
PV is insufficient
(PV+battery
load)
The battery discharges power to the load, and once its capacity
reaches Min SOC, it automatically ceases discharging.
Note:
Charge battery to: The battery SOC charged from grid. 10% by default, range is 10%~100%.
Min SOC: Minimum SOC of the battery under grid connection. 10% by default, range is
10%~100%.
Export Control: The power exported to the grid. 300000 W by default.
Charge & Discharge Period
You can set two configurable working periods: forced charging period and allowed
discharging period. The interval not in the charging & discharging period belongs to other
time periods.
Forced charging period (Default period: 00:00~00:00, closed by default)
In the forced charging period, the inverter will charge the battery first untill the battery SOC
reaches the specified Charge battery to value set in each working mode. You have the
option to configure the inverter to either draw power from the grid or not.
Allowed discharging period (Default period: 00:00~23:59)
In the allowed discharging period, the inverter will allow the battery to discharge and
charge power in accordance with the working mode and load conditions.
Period not set as forced charging or allowed dicharging period
In this period, the inverter will allow the battery to charge but can not discharge power.
NOTICE!
The charging and discharging period is only applicable for self-use mode, feed-in
priority and backup mode. The priority of forced charging period is higher than all
working modes.