41
Electrical Connection
Item Part Description Source
E System switch Select an ON-OFF switch
Prepared by
user
F
(Optional) SolaX
communication device
SolaX DataHub, Adapter Box G2 and
EV-Charger, etc are supported. Select
the device as needed.
Purchased
from SolaX
Generator
Select a generator equipped with
an Automatic Transfer Switching
Equipment (ATS), and the rated output
power of the generator should be
greater than the sum of the load power
and the battery charging power.
Prepared by
user
G Meter/CT
SolaX authorized DTSU666, DTSU666-
CT and CT are supported.
Purchased
from SolaX
H
Micro circuit breaker
(MCB)
Select an appropriate MCB according
to the local regulations to ensure
the inverter can be securely
disconnected from the grid when
an emergency occurs. Refer to "5.3
Additionally Required Materials" for the
recommended specifications of MCB.
Prepared by
user
I
(Optional) Monitoring
dongle
Only SolaX monitoring dongle is
supported.
Purchased
from SolaX
Table 8-3 Descriptions of cables
Item Cable Description Source
1
PV DC input power
cable
Refer to "5.3 Additionally
Required Materials"
Prepared by user
2 Battery power cable / Delivered with battery
3
Battery communication
cable
Refer to "5.3 Additionally
Required Materials"
Prepared by user
4 Communication cable Prepared by user
5 Communication cable Prepared by user
6 Communication cable Prepared by user
7 AC output cable Prepared by user
8 PE cable Prepared by user