57
Electrical Connection
Pin Pin assignment Description
4 485A For other devices connection,
such as SolaX Adapter Box G2,
EV-Charger, DataHub, etc.
5 485B
6 GND
7 Drycontact_A(out)
For generator connection
8 Drycontact_B(out)
* Pin 3 (+13V) and Pin 6 (GND) cannot be connected together in the process of cable
connection. Please wrap the two pins with insulating tape if the two pins do not need to be
connected.
Wiring procedure
Step 1: Prepare a CAT5E network cable, thread the network cable through waterproof
connector (part D) and strip off the 15 mm insulation of the cable.
15 mm
Figure 8-31 Stripping the insulation
Step 2: Insert the stripped section into the RJ45 terminal (from part D). Crimp it tightly
with a crimping tool for RJ45. Pay attention to the pin order of RJ45 terminal.
Use a network cable tester to check if the cable has been correctly and properly
crimped before connecting to inverter.
1 2 3 4 5 6 7 8
1 8
1) White with orange stripes
2) Orange
3) White with green stripes
4) Blue
5) White with blue stripes
6) Green
7) White with brown stripes
8) Brown
Figure 8-32 Crimping the network cable