Operation on LCD
Battery: Information of battery contains the voltage, current, power, SOC, cell
temperature and BMS connection status. Positive value with power means
charging; negative value means discharging.
====System Status====
>Battery
On-grid
======Battery1=======
>U 0.0V
I 0.0A
P 0W
======Battery1=======
SoC 0%
Cell Temp 20°C
BMS Connected
On-grid: Information contains the voltage, current, frequency, and output power
of Grid connection terminal. The "A", "B" and "C" in On-grid A, On-grid B and On-
grid C refers to L1, L2 and L3 respectively. The figure below will take On-grid A
as an example. Positive value with power means power output; negative value
means power input.
====System Status====
>On-Grid
EPS
======On-grid A======
>Ua 0.0V
Ia 0.0A
PaOut 0W
======Frequency======
Fa 0.00Hz
Fb 0.00Hz
Fc 0.00Hz
EPS: Information contains apparent power, voltage, current, active power and
frequency of EPS (off-grid) connection terminal when it is disconnected from
the grid. The "A", "B" and "C" in EPS A, EPS B and EPS C refers to L1, L2 and L3
respectively. The figure below will take EPS A as an example.
====System Status====
>EPS
Meter/CT
=====EPS_Spower=====
>PaS 0.0W
PbS 0.0W
PcS 0.0W
=======EPS A=======
Ua 0.00V
Ia 0.00A
PaActive 0.00W
======Frequency======
Freq
0.00Hz
Meter/CT: Information contains feed-in power of L1, L2 and L3 detected by the
connected meter or CT. Positive value with Pfeedin means power fed into grid;
negative value means power taken from grid.
====System Status====
EPS
>Meter/CT
=====Meter/CT=====
>Pfeedin A 0.0W
Pfeedin B 0.0W
Pfeedin C 0.0W