Setting
Setting
Min SOC
30%
Backup mode
Backup mode
Charge battery to
50%
94
95
7 ) Charge and discharge time
Here you can set the charge and discharge time period.
If two charging and discharging periods are needed, turn on the charging
and discharging period 2 and set the period.
8 ) Peak shaving mode
Forced Charg Period
Start Time
00:00
Char&Disc Period
Forced Charg Period
End Time
00:00
Char&Disc Period
Allowed Disc Period
Start Time
00:00
Char&Disc Period
Allowed Disc Period
End Time
00:00
Char&Disc Period
Char&Disc Period2
Char&Disc Period
Function Control
Enable
Char&Disc Period2
Char&Disc Period2
Forced Charg Period
Start Time
00:00
Char&Disc Period2
Forced Charg Period
End Time
00:00
Allowed Disc Period
Start Time
00:00
Char&Disc Period2
Allowed Disc Period
End Time
00:00
Char&Disc Period2
5 ) Feed-in Priority
In this mode, you can set the power reserve percentage of the minimum
battery state, set whether the power can be taken from the mains side to
charge the battery, and set the amount of power to charge the battery.
For example: set the reserved minimum SOC of the battery capacity to
"10%", which means that when the battery has been discharged to 10% of
the battery capacity, the battery is not allowed to continue to discharge;
Charge battery to is set to 50%, indicating that the mains is allowed to
charge the battery at 50%.
Min SOC:
10%
Feed-in Priority
Charge battery to
50%
Feed-in Priority
6 ) Backup mode
In this mode, you can set the power reserve percentage of the
minimum battery state, set whether the power can be taken from the
mains side to charge the battery, and set the amount of power to
charge the battery.
For example: set the reserved minimum SOC of the battery capacity to
"30%", which means that when the battery has been discharged to 30%
of the battery capacity, the battery is not allowed to continue to
discharge;
Charge battery to is set to 50%, indicating that the mains is allowed to
charge the battery at 50%.
Min SOC
10%
Self Use Mode
Charge from grid
Enable
Self Use Mode
Charge battery to
10%
Self Use Mode
Min SOC
Charge from grid
Self Use Mode
This setting is for enabling peak shaving mode.
"DisChgPeriod1" or "DisChgPeriod2" are two discharging periods you can set.
Set "ShavingStartTime1" (default value: 7:00) and "ShavingEndTime1 (default
value: 15:00) under "DisChgPeriod1" and "ShavingStartTime2 (default value:
19:00) and "ShavingEndTime2" (default value: 23:00) under "DisChgPeriod2"
to dene the peak hours of electricity.
Set "PeakLimits1/2" to limit the power that loads get from the grid. Once the
power of loads exceeds "peak limits" during the peak hours, the PV and
battery will discharge energy for loads and thus reduce the amount of energy
purchased from the grid. In non-peak hours, discharging of the battery is not
allowed. If you want to get electricity from the grid, set "ChargeFromGrid" to
"Enable". "Disable" is the default setting. When you select "Enable and the
actual battery SOC is less than "MAX_SOC (settable)", the battery can be
charged from the grid at no more than "ChargePowerLimits" (settable)
power.
Range of "ChargePowerLimits": 0 W~rated power ( W )
The range of "MAX_SOC" is 10%100%; the default value is 50%.
Range of "Reserved_SOC": 10%100%; the default value is 50%.
Reserved_SOC" is the battery capacity saved for the next peak shaving in the
non-peak shaving period.