Product Overview
NOTICE!
• When the battery supplies power to the load, the available capacity of the battery
decreases as the SOC decreases.
2.7.7 Manual Mode
This working mode is only for the professional technical personnel to perform debugging
and maintenance. It includes Forced Discharge, Forced Charge and Stop chrg&dischrg.
The system will restore to the original working mode after six hours Manual mode set.
2.7.8 Export Control Function
Solar export control is a limit on the amount of energy your solar system that can export
into the grid. You have a set limit on how much energy you can export to the grid.
How Export Control works
• CT/meter required
• Correct setting of the limit value of Export Control through inverter. (For parallel
system, set on the master inverter)
PV
Load: 6 kW
2 kW
Meter
4 kW
2 kW
Grid
Inverter: 30 kW
2 kW
2 kW
2 kW
Figure 2-15 Zero export control with Phase Unbalance disabled