110
Operation on LCD
b. Select the equipment which needs to be connected and set the corresponding
Braud Rate and Address. Take EV Charger as an example, The default baud rate is
9600.
=====Internal485=====
>Function Control
EV Charger
>Braud Rate
9600
>EV Charger Addr:
70
=====Internal485===== =====Internal485=====
NOTICE!
When two equipments need to be connected at the same time, the Braud Rate and
address of the two equipments shall be set to the same.
c. Check the connectiong status. For the connection status of Datahub, please
check it on the Datahub and the external equipment.
=====Internal485=====
>EV Charger COM STAT
Connected
NOTICE!
Please refer to "8.6 COM 1 Communication Connection" for specific wiring
connection of datahub, EV Charger and Adapter Box.
Battery Charge EVC
You can set Enable to allow the battery to discharge energy to EV Charger. When you set
to Disable, battery discharging energy to EV Charger is not allowed.
===Battery charge EVC===
>Function Control
Enable
Advanced Password
You can reset the advanced password here.
10.8 About
Displaying path: Menu > About
Here shows the basic information of the inverter, battery and internal code. Aftering
entering into the About interface, you can check those information.
Inverter
»
Inverter SN, Register SN, ARM Verion, DSP version, On-grid Runtime, EPS
Runtime.
Battery 1 and Battery 2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolaX Power X3-ULT-15KP and is the answer not in the manual?

SolaX Power X3-ULT-15KP Specifications

General IconGeneral
BrandSolaX Power
ModelX3-ULT-15KP
CategoryInverter
LanguageEnglish

Related product manuals