28
Preparation before Installation
5.3 Additionally Required Materials
Table 5-10 Additionally required wires
No. Required Material Type
Conductor
Cross-section
1 PV wire
Dedicated PV wire with a voltage
rating of 1000 V, a temperature
resistance of 105
,
a fire
resistance grade of VW-1
4 mm²-6 mm²
2
Communication
wire 1
Network cable CAT5E / CAT6 /
3
Communication
wire 2
Four-core signal cable
0.25 mm²-0.3
mm²
4
Grid and EPS
wire
Five-core copper cable
10 mm² /
16 mm²
5
Additoinal PE
wire
Conventional yellow and green
wire
Consistent with
Grid and EPS
wire
Table 5-11 Micro-breaker recommended for Grid connection
Model
X3-ULT-
15KP
X3-ULT-
15K
X3-ULT-
19.9K
X3-ULT-
20K
X3-ULT-
20KP
X3-ULT-
25K
X3-ULT-
30K
Micro-
breaker
32 A 32 A 50 A 50 A 50 A 63 A 63 A
Table 5-13 Micro-breaker recommended for EPS connection
Model
X3-ULT-
15KP
X3-ULT-
15K
X3-ULT-
19.9K
X3-ULT-
20K
X3-ULT-
20KP
X3-ULT-
25K
X3-ULT-
30K
Micro-
breaker
32 A 32 A 40 A 40 A 40 A 63 A 63 A