1. TABLE OF CONTENT
1. Table of content ....................................................................................................................... 2
2. Safety & Warnings ................................................................................................................... 4
2.1 Safety ......................................................................................................................................... 4
2.2 Attention ..................................................................................................................................... 4
2.3 Warnings .................................................................................................................................... 4
3. Technical Data ......................................................................................................................... 5
3.1 Introduction ................................................................................................................................ 5
3.2 Rating, Frames sizes and Weights ............................................................................................ 5
Refer to section
5 page 15 for detailed dimensional drawings ......................................................... 5
3.3 TPS Selection ............................................................................................................................ 5
3.4 Ordering Information .................................................................................................................. 6
3.5 Mains and control description .................................................................................................... 7
3.6 Input / Output indication ............................................................................................................. 9
3.7 Load Connections ...................................................................................................................... 9
3.8 Modes of operation .................................................................................................................... 9
3.8.1 Zero Crossing .................................................................................................................. 9
3.8.2 Phase Control ................................................................................................................ 10
3.8.3 Phase control to zero crossing (Soft start) .................................................................... 10
3.8.4 Phase Control-Power .................................................................................................... 10
3.9 Synchronized mode ................................................................................................................. 11
4. Recommended Wiring Scheme ............................................................................................ 12
4.1 Load connection schemes ....................................................................................................... 12
4.2 INSIDE DELTA Wiring ............................................................................................................. 13
4.3 Typical control scheme ............................................................................................................ 13
4.4 Communication and Synchronization wiring ............................................................................ 14
4.5 Wiring Notes ............................................................................................................................ 14
4.5.1 Short Circuit Protection ................................................................................................. 15
4.5.2 Transient Protection ...................................................................................................... 15
5. Dimensions ............................................................................................................................ 15
5.1 400-690VAC Models ................................................................................................................ 15
5.2 1000VAC Models ..................................................................................................................... 19
6. Installation .............................................................................................................................. 20
6.1 Prior to Installation ................................................................................................................... 20
6.2 Mounting ......................................................................................................................
............ 20
6.3 Temperature range & heat dissipation ..................................................................................... 20
6.4 Protection bus-bars covers for power terminals. ...................................................................... 20
6.5 Jumpers settings for analogue input configuration .................................................................. 21
6.6 Dip switches settings for analogue output optional PCB ......................................................... 21
7. Control Keypad ...................................................................................................................... 23
7.1 LCD Arrangement .................................................................................................................... 23
7.2 Push-buttons ............................................................................................................................ 23
7.3 Status LEDs. ............................................................................................................................ 24
7.4 Reviewing and modifying parameters ...................................................................................... 24
7.5 Special actions performed by the key-pad. .............................................................................. 24
7.5.1 Run self test, Software version, default parameters and clear statistical data .............. 24
7.6 Mode Pages ............................................................................................................................. 25
7.7 Mode Pages, parameters & default values .............................................................................. 26
7.7.1 Main parameters settings – page 1 ............................................................................... 28
7.7.2 I/O Parameters – page 2 ............................................................................................... 30
7.7.3 Protection Parameters – page 3 .................................................................................... 32

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Solcon TPS and is the answer not in the manual?

Solcon TPS Specifications

General Specifications IconGeneral Specifications
rated current8-1500A
rated voltage120 - 1000VAC +10% -15%
control voltage120 or 230VAC, 110VDC+10% -15%
frequency50 / 60 Hz
controlled phasesThree
short-circuit current25kA
rated insulation voltage690V (120-690V mains models), 1000V (1000V mains models), 250V (control circuits)
rated impulse withstand6kV (Mains), 2.5kV (control)
degree of protectionIP00
pollution degree3
ambient temperature operating-10 – + 50°C
ambient temperature storage-20 – + 70°C
altitudeTo 1000 m ASL W/O de-rating
coolingForced air (fans)
number of CTsThree
connection modesWye - Neutral connected / not connected
Control Specifications IconControl Specifications
control methodDigital
firing methodZero crossing, Phase control, Phase control-power
on-off time cycle1000 – 10000 mSec.
analog input0-10V >100KΩ / 4-20 mA, 0-20mA <100Ω
control inputsStart/Stop (with internal 0-60 sec time delays), Aux. contact
output relays3 programmable (1-C/O) (8A/250VAC)
maximum breaking capacity AC2000 VA
max. DC load breaking capacity8A at 30VDC.
synchronizationOne master and 2-9 connected slaves
Fan and TPS Consumption Ratings IconFan and TPS Consumption Ratings
TPS 8-31A consumption21W
TPS 44-72A consumption36W
TPS 85-105A consumption26W
TPS 145-170A consumption35W
TPS 210-460A consumption64W
TPS 580-820A consumption100W
TPS 55-200A 1000V consumption40W