4 • Safety & Warnings
________________________________________________________________________________________________
2. SAFETY & WARNINGS
2.1 Safety
1
Read this manual carefully before operating the equipment and follow its
instructions.
2
Installation, operation and maintenance should be in strict accordance
with this manual, national codes and good practice.
3
Installation or operation not performed in strict accordance with these
instructions will void manufacturer warranty.
4
Disconnect all power inputs before servicing the TPS and/or the load.
5
After installation, check and verify that no parts (bolts, washers, etc) have
fallen into the TPS.
2.2 Attention
1
This product was designed for compliance with IEC 947-4-3 for class A
equipment. TPS 1000V were also type tested to meet this standard.
2
Use of the product in domestic environments may cause radio
interference, in which case, the user may be required to employ
additional mitigation methods.
3
Utilization category is AC-51: 1,4 x Ie – 1 s, uninterrupted duty. For
further information, see Technical Specification
2.3 Warnings
1
Internal components and PCBs are at mains potential when the TPS is
connected to mains. This voltage is extremely dangerous and will cause
death or severe injury if contacted.
2
When TPS is connected to mains, even if control voltage is disconnected,
full voltage may appear on its output.
3
The TPS must be grounded to ensure correct operation, safety and to
prevent damage.
4
Check that Power Factor capacitors are not connected to the output side
of the soft TPS.
5
Do not interchange line and load connections
6
Phase Control Firing, may cause Radio interferences, in which case the
user may be required to employ additional mitigation methods.
The company reserves the right to make any improvements or modifications to its products without
prior notice.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Solcon TPS and is the answer not in the manual?

Solcon TPS Specifications

General Specifications IconGeneral Specifications
rated current8-1500A
rated voltage120 - 1000VAC +10% -15%
control voltage120 or 230VAC, 110VDC+10% -15%
frequency50 / 60 Hz
controlled phasesThree
short-circuit current25kA
rated insulation voltage690V (120-690V mains models), 1000V (1000V mains models), 250V (control circuits)
rated impulse withstand6kV (Mains), 2.5kV (control)
degree of protectionIP00
pollution degree3
ambient temperature operating-10 – + 50°C
ambient temperature storage-20 – + 70°C
altitudeTo 1000 m ASL W/O de-rating
coolingForced air (fans)
number of CTsThree
connection modesWye - Neutral connected / not connected
Control Specifications IconControl Specifications
control methodDigital
firing methodZero crossing, Phase control, Phase control-power
on-off time cycle1000 – 10000 mSec.
analog input0-10V >100KΩ / 4-20 mA, 0-20mA <100Ω
control inputsStart/Stop (with internal 0-60 sec time delays), Aux. contact
output relays3 programmable (1-C/O) (8A/250VAC)
maximum breaking capacity AC2000 VA
max. DC load breaking capacity8A at 30VDC.
synchronizationOne master and 2-9 connected slaves
Fan and TPS Consumption Ratings IconFan and TPS Consumption Ratings
TPS 8-31A consumption21W
TPS 44-72A consumption36W
TPS 85-105A consumption26W
TPS 145-170A consumption35W
TPS 210-460A consumption64W
TPS 580-820A consumption100W
TPS 55-200A 1000V consumption40W