Frequency Inverter ST600 Series High-Performance Multifunction VFD Basic Operation Instructions
-100-
Command switches to keypad
When this terminal is valid, the running command channel will
switch to keypad compulsorily. If this function becomes invalid,
the running command channel will revert to the original state.
Command switches to terminal
When this terminal is valid, the running command channel will
switch to terminal compulsorily. If this function becomes invalid,
the running command channel will revert to the original state.
Command switches to
communication
When this terminal is valid, the running command channel will
switch to communication compulsorily. If this function becomes
invalid, the running command channel will revert to the original
state.
When this terminal is valid, motor pre-exciting will be started
until this terminal becomes invalid.
Zero out power consumption
quantity
After this command becomes valid, the power consumption
quantity of the VFD will be zeroed out.
Maintain power consumption
quantity
When this command is valid, current operation of the VFD will
not impact the power consumption quantity.
Source of upper torque limit
switches to keypad
When this command is valid, the upper limit of the torque will
be set by keypad
Position reference point input
Valid only for S1, S2, and S3.
Disable spindle orientation
Spindle orientation is invalid.
Spindle zeroing/local position
zeroing
Spindle positioning is triggered.
Spindle zero position selection
1
Spindle zero position selection 1.
Spindle zero position selection
2
Spindle zero position selection 2.
Spindle scale division selection
1
Spindle scale division selection 1.
Spindle scale division selection
2
Spindle scale division selection 2.
Spindle scale division selection
3
Spindle scale division selection 3.
Position/speed control
switchover terminal
Terminal for switching between position control and speed
control.
Pulse input is invalid when the terminal is valid.
Used to clear the input deviation of position loop.
Switch position proportional
gains
Used to switch position proportional gains.
Enable cyclic digital positioning
Cyclic positioning can be enabled when digital positioning is
valid.