EasyManua.ls Logo

Sourcetronic ST600 - P93-Tension Control Status Viewing

Sourcetronic ST600
390 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Frequency Inverter ST600 Series High-Performance Multifunction VFD Function parameter list
-250-
P92.12
Determination
delay time of
feeding interrupt
detection
0.160.0s
1.0s
P92.13
Handling mode of
feeding interrupt
0x0000x111
Ones place: Stop mode
0: Decelerate to stop in emergency manner
1: Coast to stop
Tens place: Alarm mode
0: Stop in enabled stop mode without reporting an
alarm
1: Report an alarm and coast to stop
Hundreds place: Roll diameter memory function of
feeding interrupt
0: Disable
1: Enable
0x000
P92.14
Stop braking
frequency
0.00300.00Hz
1.50Hz
P92.15
Stop braking time
0.0600.0s
0.0s
P93––Tension control status viewing
Function
code
Name
Description
Default
value
Modify
P93.00
Actual control
mode
03
0: Invalid tension control
1: Close-loop tension speed control
2: Open loop tension torque control
3: Close-loop tension torque control
0
P93.01
Actual winding/
unwinding mode
01
0: Winding
1: Unwinding
0
P93.02
Initial roll diameter
0.05000.0mm
0.0mm
P93.03
Reset roll diameter
0.05000.0mm
0.0mm
P93.04
Roll diameter
change rate
0.00655.35 mm/s
0.00 mm/s
P93.05
Present roll
diameter
0.05000.0mm
0.0mm
P93.06
Roll diameter for
linear speed
calculation
0.05000.0mm
0.0mm
P93.07
Set linear speed
0.06000.0 m/min
0.0 m/min
P93.08
Present linear
0.06000.0 m/min
0.0 m/min