Frequency Inverter ST600 Series High-Performance Multifunction VFD Function parameter list
-229-
0: Incremental encoder
1: Resolver-type encoder
2: Sin/Cos encoder
3: Endat absolute encoder
Number of pulses generated when the encoder revolves
for one circle.
Setting range: 0–60000
Ones: AB direction
0: Forward
1: Reverse
Tens: Z pulse direction (reserved)
0: Forward
1: Reverse
Hundreds: CD/UVW pole signal direction
0: Forward
1: Reverse
Detection time of
encoder offline
fault
Detection time of
encoder reversal
fault
Filter times of
encoder detection
Setting range: 0x00–0x99
Ones: Low-speed filter times, corresponds to 2^(0–
9)×125us.
Tens: High-speed filter times; corresponds to 2^(0–
9)×125us.
Speed ratio
between encoder
mounting shaft
and motor
Users need to set this parameter when the encoder is not
installed on the motor shaft and the drive ratio is not 1.
Setting range: 0.001–65.535
Control
parameters of
synchronous
motor
0x0000–0xFFFF
Bit0: Enable Z pulse calibration
Bit1: Enable encoder angle calibration
Bit2: Enable SVC speed measurement
Bit3: Reserved
Bit4: Reserved