Frequency Inverter ST600 Series High-Performance Multifunction VFD Function parameter list
-243-
P90––Tension control in speed mode
Function
code
Name
Description
Default
value
Modify
P90.00
Tension control
mode
0: Invalid
1: Speed mode
2: Open-loop torque mode
3: Closed-loop torque mode
Note: The value 0 indicates tension control is invalid.
Select a non-0 value to enable the tension control
function.
0
P90.01
Winding/unwinding
mode
0: Winding
1: Unwinding
Note: The motor forward rotation direction is the winding
direction. When using the tension control mode, check
whether the motor rotation direction is correct in the
winding mode; if not, change the rotation direction by
swapping two phase wires of the motor. After the rotation
direction is corrected, the winding mode can be switched
to the unwinding mode by setting P90.01 to 1 or
changing the winding/unwiding switchover terminals.
0
P90.02
Reel mechanical
transmission rate
0.01600.00
=Motor rotation speed/Reel rotation speed=Reel
diameter/Motor shaft diameter
1.00
P90.03
Max. linear speed
0.06000.0 m/min
1000.0
m/min
P90.04
Input source of
linear speed
0: Keypad
1: AI1
2: AI2
3: AI3
4: High-speed pulse HDI
5: Main traction encoder frequency-division input
0
P90.05
Linear speed set
through keypad
0.0100.0%
20.0%
P90.06
Diameter of main
traction
0.06000.0mm
99.0mm
P90.07
Main traction drive
ratio
0.00060.000
1.000
P90.08
Linear speed ACC
time
0.00600.00s
0.00s
P90.09
Linear speed DEC
time
0.00600.00s
0.00s
P90.10
Tension setting
0x000x14
Ones place: Tension setting source
0x00