Frequency Inverter ST600 Series High-Performance Multifunction VFD Function parameter list
-244-
0: Keypad
1: AI1
2: AI2
3: AI3
4: High-speed pulse HDI
Tens place: Multiplier of max. tension (P90.12)
0: 1
1: 10
P90.11
Tension set
through keypad
0.0100.0%
10.0%
P90.12
Max. tension
When the tens place of P90.10 is 0, the setting range is
060000N.
When the tens place of P90.10 is 1, the setting range is
(060000)*10N.
1000N
P90.13
Roll diameter
calculation mode
0: Not calculated
1: AI1
2: AI2
3: AI3
4: High-speed pulse HDI
5: Linear speed
6: Thickness (of wire)
7: Thickness (of strip)
0
P90.14
Roll diameter
calculation delay
time
0.0100.0s
1.0s
P90.15
Min. roll diameter
0.0mmP90.16
50.0mm
P90.16
Max. roll diameter
P90.15–5000.0mm
1000.0
mm
P90.17
Initial roll diameter
1
P90.15–P90.16 mm
100.0 mm
P90.18
Initial roll diameter
2
P90.15–P90.16 mm
100.0 mm
P90.19
Initial roll diameter
3
P90.15–P90.16 mm
100.0 mm
P90.20
Linear speed roll
diameter
calculation filter
time
0.00060.000s
2.000s
P90.21
Linear speed roll
diameter
calculation
restriction
0x000x11
Ones place:
0:No
1: Restrict changes in reverse direction
Tens place:
0: No
0x00