Frequency Inverter ST600 Series High-Performance Multifunction VFD Function parameter list
-245-
1: Automatic restriction according to running frequency
and material thickness
P90.22
Material thickness
0.001–65.535mm
0.010 mm
P90.23
Number of coils
per layer
1–10000
1
P90.24
Revolution
counting function
selection
02
0: Digital terminal input
1: PG card input
(Applicable to thickness calculation method)
2: Running frequency
(No input automatic revolution counting)
0
P90.25
Number of pulses
per revolution
1–60
1
P90.26
Roll diameter set
value
0.0100.0%
80.0%
P90.27
Roll diameter reset
setting
0x00000x1111
Ones place: At stop
0: Remain current roll diameter
1: Restore to initial roll diameter
Tens place: Power off at running
0: Remain current roll diameter
1: Restore to initial roll diameter
Hundreds place: Reach the roll diameter set value
0: Remain current roll diameter
1: Restore to initial roll diameter
Thousands place: Terminal reset limitation
0: Reset allowed at running
1: Reset only allowed at stop
0x1000
P90.28
Tension PID output
reference
01
0: Max. value
1: Given value
0
P90.29
Tension PID
parameter source
05
0: First group of P90
1: Roll diameter (max. roll diameter)
2: Main reference frequency (max. Frequency)
3: Running linear speed (max. linear speed)
4: Deviation (Reference 100%)
5: Terminal
0
P90.30
Group 1
proportional gain
0.00030.000
0.030
P90.31
Group 1 integral
time
0.0030.00s
5.00s
P90.32
Group 1
differential time
0.0010.00s
0.00s