EasyManua.ls Logo

Sourcetronic ST600 - P22-Spindle Positioning

Sourcetronic ST600
390 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Frequency Inverter ST600 Series High-Performance Multifunction VFD Function parameter list
-225-
P21.32
Pulse reference
feedforward
source
0x00x1
0x0
P21.33
Set value of
clearing encoder
count
0–65535
0
P22––Spindle positioning
Function
code
Name
Description
Default
value
Modify
P22.00
Spindle positioning
mode selection
0x00000xFFFF
Bit0: Enable spindle positioning
0: Disable
1: Enable
Bit1: Select spindle positioning reference point
0: Z pulse input
1: S2/S3/S4 terminal input
Bit2: Search for reference point
0: Search the reference point only once
1: Search the reference point every time
Bit3: Enable reference point calibration
0: Disable
1: Enable
Bit4: Positioning mode selection 1
0: Set direction positioning
1: Near-by direction positioning
Bit5: Positioning mode selection 2
0: Forward positioning
1: Reverse positioning
Bit6: Zeroing command selection
0: Electric level mode
1: Pulse mode
Bit7: Reference point calibration mode
0: Calibrate at the first time
1: Calibrate in real time
Bit8: Action selection after zeroing signal cancellation
(electric level type)
0: Switch to speed mode
1: Position lock mode
Bit9: Positioning completion signal selection
0: Electric level signal
1: Pulse signal
Bit10: Z pulse signal source
0: Motor
1: Spindle
Bit11–15: Reserved
0x0000