EasyManua.ls Logo

Sourcetronic ST600 - Page 136

Sourcetronic ST600
390 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Frequency Inverter ST600 Series High-Performance Multifunction VFD Basic Operation Instructions
-129-
70: EC PT100 detected overheating (OtE1)
71: EC PT1000 detected overheating (OtE2)
72: EtherNet/IP communication timeout (E-
EIP)
73: No upgrade bootload (E-PAO)
74: AI1 disconnected (E-AI1)
75: AI2 disconnected (E-AI2)
76: AI3 disconnected (E-AI3)
P07.33
Running frequency at present
fault
0.00Hz–P00.03
0.00Hz
P07.34
Ramps reference frequency at
present fault
0.00Hz–P00.03
0.00Hz
P07.35
Output voltage at present fault
0–1200V
0V
P07.36
Output current at present fault
0.0–6300.0A
0.0A
P07.37
Bus voltage at present fault
0.0–2000.0V
0.0V
P07.38
Max. temperature at present
fault
-20.0–120.0°C
0.0°C
P07.39
Input terminal state at present
fault
0x0000–0xFFFF
0
P07.40
Output terminal state at
present fault
0x0000–0xFFFF
0
P07.41
Running frequency at last fault
0.00Hz–P00.03
0.00Hz
P07.42
Ramps reference frequency at
last fault
0.00Hz–P00.03
0.00Hz
P07.43
Output voltage at last fault
0–1200V
0V
P07.44
Output current at last fault
0.0–6300.0A
0.0A
P07.45
Bus voltage at last fault
0.0–2000.0V
0.0V
P07.46
Max. temperature at last fault
-20.0–120.0°C
0.0°C
P07.47
Input terminal state at last fault
0x0000–0xFFFF
0
P07.48
Output terminal state at last
fault
0x0000–0xFFFF
0
P07.49
Running frequency at last but
one fault
0.00Hz–P00.03
0.00Hz
P07.50
Ramps reference frequency at
last but one fault
0.00Hz–P00.03
0.00Hz
P07.51
Output voltage at last but one
fault
0–1200V
0V
P07.52
Output current at last but one
fault
0.0–6300.0A
0.0A
P07.53
Bus voltage at last but one
fault
0.0–2000.0V
0.0V
P07.54
Max. temperature at last but
-20.0–120.0°C
0.0°C

Table of Contents