Frequency Inverter ST600 Series High-Performance Multifunction VFD Function parameter list
-212-
torque control
P17.45
Inertia compensation
torque
-100.0%–100.0%
0.0%
P17.46
Friction
compensation torque
-100.0%–100.0%
0.0%
P17.47
Motor pole pairs
0–65535
0
P17.48
VFD overload count
value
0–65535
0
P17.49
Frequency set by A
source
0.00P00.03
0.00Hz
P17.50
Frequency set by B
source
0.00P00.03
0.00Hz
P17.51
PID proportional
output
-100.0%–100.0%
0.0%
P17.52
PID integral output
-100.0%–100.0%
0.0%
P17.53
PID differential output
-100.0%–100.0%
0.0%
P17.54
Current PID
proportional gain
0.00100.00
0.00
P17.55
Current PID integral
time
0.0010.00s
0.00s
P17.56
Current PID
differential time
0.0010.00s
0.00s
P17.57
Current step of multi-
step speed
0–15
0
P17.58
Peak-to-peak value at
100Hz frequency
component (square-
wave orthogonal
function detected)
0.0300.0V
Peak-to-peak value of bus voltage fluctuation at
100Hz frequency component, which is detected by
using a square-wave orthogonal function
0.0V
P17.59
Peak-to-peak value at
100Hz frequency
component (sine-wave
orthogonal function
detected)
0.0300.0V
Peak-to-peak value of bus voltage fluctuation at
100Hz frequency component, which is detected by
using a sine-wave orthogonal function
0.0V