Frequency Inverter ST600 Series High-Performance Multifunction VFD Function parameter list
-214-
P18.15
Low bit of encoder
pulse count value
0–65535
0
P18.16
Main control board
measured speed
value
-3276.8–3276.7Hz
0.0Hz
P18.17
Pulse command
frequency
Pulse command (A2, B2 terminal) is converted to the set
frequency, and it is valid under pulse position mode and
pulse speed mode.
Range: 0–655.35Hz
0.00Hz
P18.18
Pulse command
feedforward
Pulse command (A2, B2 terminal) is converted to the set
frequency, and it is valid under pulse position mode and
pulse speed mode.
Range: 0–655.35Hz
0.00Hz
P18.19
Position regulator
output
-327.68–327.67Hz
0.00Hz
P18.20
Count value of
resolver
Count value of resolver.
Range: 0–65535
0
P18.21
Resolver angle
The pole position angle read according to the resolver-
type encoder.
Range: 0.00–359.99
0.00
P18.22
Pole angle of
closed-loop
synchronous
motor
Current pole position.
Range: 0.00–359.99
0.00
P18.23
State control word
2
0x0000–0xFFFF
0x0000
P18.24
High bit of count
value of pulse
reference
0–65535
0
P18.25
Low bit of count
value of pulse
reference
0–65535
0
P18.26
PG card measured
speed value
-3276.8–3276.7Hz
0.0Hz
P18.27
Encoder UVW
sector
0–7
0
P18.28
Encoder PPR
(pulse-per-
revolution) display
0–65535
0
P18.29
Angle
compensation
value of
synchronous
motor
-180.0180.0
0.0