Frequency Inverter ST600 Series High-Performance Multifunction VFD Function parameter list
-218-
P20.07
Control
parameters of
synchronous
motor
0x00000xFFFF
Bit0: Enable Z pulse calibration
Bit1: Enable encoder angle calibration
Bit2: Enable SVC speed measurement
Bit3: Select resolver speed measurement mode
Bit4: Z pulse capture mode
Bit5: Do not detect encoder initial angle in v/f control
Bit6: Enable CD signal calibration
Bit7: Disable sin/cos sub-division speed measurement
Bit8: Do not detect encoder fault during autotuning
Bit9: Enable Z pulse detection optimization
Bit10: Enable initial Z pulse calibration optimization
Bit11: Reserved
Bit12: Clear Z pulse arrival signal after stop
Bit13: Reserved
Bit14: Detect Z pulse after one rotation
Bit15: Reserved
0x0003
P20.08
Enable Z pulse
offline detection
0x00–0x11
Ones: Z pulse
0: Do not detect
1: Enable
Tens: UVW pulse (for synchronous motor)
0: Do not detect
1: Enable
0x10
P20.09
Initial angle of Z
pulse
Relative electric angle of encoder Z pulse and motor pole
position.
Setting range: 0.00–359.99
0.00
P20.10
Initial angle of the
pole
Relative electric angle of encoder position and motor
pole position.
Setting range: 0.00–359.99
0.00
P20.11
Autotuning of initial
angle of pole
0–3
1: Rotary autotuning (DC brake)
2: Static autotuning (suitable for resolver-type encoder,
sin/cos with CD signal feedback)
3: Rotary autotuning (initial angle identification)
0
P20.12
Speed
measurement
optimization
selection
0: No optimization
1: Optimization mode 1
2: Optimization mode 2
1
P20.13
CD signal zero
offset gain
0–65535
0
P20.14
Encoder type
selection
0x00–0x11
Ones: Incremental encoder
0: without UVW
1: with UVW
0x00