Frequency Inverter ST600 Series High-Performance Multifunction VFD Basic Operation Instructions
-63-
P03.15
Source of upper limit
frequency setup of reverse
rotation in torque control
0: Keypad (P03.17)
111: the same as P03.14
0
P03.16
Keypad limit value of upper
limit frequency of forward
rotation in torque control
Value range: 0.00 HzP00.03 (max. output
frequency)
50.00Hz
P03.17
Keypad limit value of upper
limit frequency of reverse
rotation in torque control
50.00Hz
P03.18
Source of upper limit setup of
the torque when motoring
0: Keypad (P03.20)
1: AI1
2: AI2
3: AI3
4: Pulse frequency HDIA
5: Modbus/Modbus TCP communication
6: PROFIBUS/CANopen/DeviceNet
communication
7: Ethernet communication
8: Pulse frequency HDIB
9: EtherCAT/PROFITNET/Ethernet IP
communication
10: PLC
11: Reserved
Note: For these settings, 100% corresponds to
the motor rated current.
0
P03.19
Source of upper limit setup of
brake torque
0: Keypad (P03.21)
110: the same as P03.18
0
P03.20
Set upper limit of the torque
when motoring via keypad
0.0300.0% (rated motor current)
180.0%
P03.21
Set upper limit of brake
torque via keypad
180.0%
P03.22
Flux-weakening coefficient in
constant power area
0.12.0
0.3
P03.23
Min. flux-weakening point in
constant power area
10%100%
20%
P03.24
Max. voltage limit
0.0120.0%
100.0%
P03.25
Pre-exciting time
0.00010.000s
0.300s
P03.32
Torque control enable
0:Disable
1:Enable
0
P03.33
Flux weakening integral gain
08000
1200