EasyManua.ls Logo

SummaSign Pro T1010 Pro - Environmental; Electrical; Summasign Pro T-Series Environmental Specifications; Summasign Pro T-Series Electrical Specifications

Default Icon
95 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SummaSign Pro T-series Cutters User’ s Manual
General Information 1-8
1.2.8. ENVIRONMENTAL
(cutter without media)
Operating Temperature
15 to 35° C 59 to 95° F
Storage temperature
-30 to 70° C -22 to 158° F
Relative humidity
35 - 85 %, non con-
densing
35 - 85 %, non con-
densing
TABLE 1-7 :
SUMMASIGN PRO T-SERIES ENVIRONMENTAL SPECIFICATIONS
IMPORTANT HINT
The use of dimensionally stable media is an essential pre-requisite to
obtaining high cut quality. Additionally, media expansion or
contraction may occur as a result of temperature variations.
To improve the dimensional stability of media, let it stabilize to the
current environmental conditions before usage, for a minimum period
of 24 hours.
1.2.9. ELECTRICAL
Mains Supply : 48-62 Hz, single phase.
Nominal line Min./Max. line Fuse
100 V AC 89 - 108 V AC 1.25 A, Slo-Blo
120 V AC 108 - 130 V AC 1.25 A, Slo-Blo
220 V AC 197 - 238 V AC 0.6 A, Slo-Blo
240 V AC 216 - 260 V AC 0.6 A, Slo-Blo
TABLE 1-8 :
SUMMASIGN PRO T-SERIES ELECTRICAL SPECIFICATIONS