82 Netra T2000 Server Administration Guide • September 2006
4. Verify that the device has been removed from the device tree.
To verify that the device has been removed from the device tree, type the following
command:
Note that c0t3d0 is now unavailable and unconfigured. The corresponding
hard drive OK-to-Remove LED is lit.
5. Remove the hard drive, as described in the server service manual.
The blue OK-to-Remove LED goes out when you remove the hard drive.
6. Install a new hard drive, as described in the server service manual.
7. Configure the new hard drive.
To configure the new hard drive, type the following command:
For example:
The green Activity LED flashes as the new disk at c1t3d0 is added to the device
tree.
# cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 scsi-bus connected configured unknown
c0::dsk/c0t0d0 disk connected configured unknown
c0::dsk/c0t1d0 disk connected configured unknown
c0::dsk/c0t2d0 disk connected configured unknown
c0::dsk/c0t3d0 unavailable connected configured unknown
c1 scsi-bus connected unconfigured unknown
c1::dsk/c1t0d0 CD-ROM connected configured unknown
usb0/1 unknown empty unconfigured ok
usb0/2 unknown empty unconfigured ok
usb1/1.1 unknown empty unconfigured ok
usb1/1.2 unknown empty unconfigured ok
usb1/1.3 unknown empty unconfigured ok
usb1/1.4 unknown empty unconfigured ok
usb1/2 unknown empty unconfigured ok
#
# cfgadm -c configure Ap-Id
# cfgadm -c configure c1::dsk/c0t3d0