Chapter 9 Troubleshooting Your Array 9-5
FIGURE 9-1 Automatic Rebuild
One member drive fails
in a logical drive
Any local spare
drive assigned to
logical drive?
Rebuild using the
local spare drive
Any global spare
drive assigned to
logical drive?
Rebuild using the
global spare drive
Waiting for
spare drive to be
added or manual
rebuild
Periodic Auto-
Detect Failure
Drive Swap Check
Time enabled?
Has the failed
drive been
replaced?
Keep detecting if drive has been replaced
or spare drive has been added
Rebuild using the
new drive
Ye s
Ye s
Ye s
Ye s
No
No
No
No

Table of Contents