9-6 Sun StorEdge 3000 Family Installation, Operation, and Service Manual • May 2004
9.3.2 Manual Rebuild
When a user applies forced-manual rebuild, the controller first determines whether
there is a local spare assigned to the logical drive. If there is, the controller
automatically starts to rebuild.
If no local spare is available, the controller searches for a global spare. If there is a
global spare, the controller begins to rebuild the logical drive. See
FIGURE 9-2.
If neither local spare nor global spare is available, the controller monitors the
channel and ID of the failed drive. When the failed drive is replaced, the logical
drive rebuild begins using the new drive. If there is no drive available for
rebuilding, the controller does not attempt to rebuild until the user applies another
forced manual rebuild.