Chapter 1 Product and Architecture Overview 1-5
information, using an “A” designator for RAID arrays and a “D” designator for
disks in a JBOD array. For example, “StorEdge 3510F D1000” identifies a JBOD array
with SES firmware version 1000, and “StorEdge 3510F A1000” identifies a Sun
StorEdge 3510 FC RAID array with firmware version 1000.
For a list of supported racks and cabinets, refer to the release notes for the model of
array that you are installing. You can find these release notes at:
http://www.sun.com/products-n-solutions/hardware/docs/
Network_Storage_Solutions/Workgroup/3510
or
http://www.sun.com/products-n-solutions/hardware/docs/
Network_Storage_Solutions/Workgroup/3511
Reliability, availability, and serviceability (RAS) are supported by:
Redundant components
Notification of failed components
Components that are replaceable while the unit is online
For information about specifications and agency approvals, see “Sun StorEdge 3510
and 3511 FC Array Specifications” on page A-1.
1.2 Field-Replaceable Units (FRUs)
This section describes the FRUs contained in the Sun StorEdge 3510 and 3511 FC
Arrays.
1.2.1 RAID I/O Controller Modules
A dual-controller configuration offers increased reliability and availability because it
eliminates a single point of failure, the controller. In a dual-controller configuration,
if the primary controller fails, the array automatically fails over to the second
controller without an interruption of data flow.
Sun StorEdge 3510 and 3511 FC array I/O controller modules are hot-serviceable.
Sun StorEdge 3510 FC array RAID controller modules provide six Fibre Channel
ports. Sun StorEdge 3511 FC array I/O controller modules provide eight Fibre
Channel ports. Single- and dual-controller models are available, with the dual-
controller version supporting active/passive and active/active configurations. Each
RAID controller is configured with 1 gigabyte (Gbyte) of cache.

Table of Contents

Other manuals for Sun Microsystems StorEdge 3000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sun Microsystems StorEdge 3000 Series and is the answer not in the manual?

Sun Microsystems StorEdge 3000 Series Specifications

General IconGeneral
BrandSun Microsystems
ModelStorEdge 3000 Series
CategoryStorage
LanguageEnglish

Related product manuals