SUNFAR C300 105
C300 series of non-sensor current vector-control inverter manual
Slave will respond(Parameter is modified)
2A 30 30 30 30 33 30 30 32 31 37 37 32 30 32 35 36 0D
5A 00 00 00 00 03 00 00 02 00 00 17 72 00 00 00 8E 0D
4.5. Order
To send control order of 0
#
slaverunning freq. is 9.99HZ
master will send
2A 30 30 34 31 31 30 33 45 37 30 31 44 35 0D
5A 00 00 04 00 11 00 00 03 E7 00 00 00 FF 0D
Slave will respond
2A 30 30 30 30 31 30 30 30 30 33 45 37 30 32 36 30 0D
5A 00 00 00 00 01 00 00 00 00 00 03 E7 00 00 00 EB 0D
4.6. Order
To modify Torque Boost F1.1 of slave as 6.0
master will send
2A 30 30 35 30 30 31 30 31 30 30 33 43 30 32 35 44 0D
5A 00 00 05 00 00 01 00 01 00 00 00 3C 00 00 00 43 0D
Slave will respond
2A 30 30 30 30 31 31 30 31 30 30 33 43 30 32 35 39 0D
5A 00 00 00 00 01 01 00 01 00 00 00 3C 00 00 00 3F 0D