SUNFAR C300 105
C300 series of non-sensor current vector-control inverter manual
Slave will respond:(Parameter is modified)
2A 30 30 30 30 33 30 30 32 31 37 37 32 30 32 35 36 0D
5A 00 00 00 00 03 00 00 02 00 00 17 72 00 00 00 8E 0D
4.5. Order Ⅵ
To send control order of 0
#
slave(running freq. is 9.99HZ)
master will send:
2A 30 30 34 31 31 30 33 45 37 30 31 44 35 0D
5A 00 00 04 00 11 00 00 03 E7 00 00 00 FF 0D
Slave will respond:
2A 30 30 30 30 31 30 30 30 30 33 45 37 30 32 36 30 0D
5A 00 00 00 00 01 00 00 00 00 00 03 E7 00 00 00 EB 0D
4.6. OrderⅤ
To modify Torque Boost F1.1 of slave as 6.0
master will send:
2A 30 30 35 30 30 31 30 31 30 30 33 43 30 32 35 44 0D
5A 00 00 05 00 00 01 00 01 00 00 00 3C 00 00 00 43 0D
Slave will respond:
2A 30 30 30 30 31 31 30 31 30 30 33 43 30 32 35 39 0D
5A 00 00 00 00 01 01 00 01 00 00 00 3C 00 00 00 3F 0D