SUNFAR C300 33
C300 series of non-sensor current vector-control inverter manual
Parameters’
Types
Function Code Name Setting range
Minimum
Setting
Manufacture
Setting
Modify
Limit
F6.16 Copy parameter function 0Forbid 1Allow 1 1
F6.17 Manufactory password 09999 1 1000
F6.18 User password 09999 1 0
Advanced
running
paramete
r unit
F6.19 Reference password 0 ~ 9999 1
F7.0
Wobble freq.
running mode
The first part of LED (form right to left)
0:Function of wobble freq. is invalid.
1:Function of wobble freq. is valid.
2:Function of wobble freq. is conditional
valid.
The second part of LED: restart mode
0:Restart according to parameters saved
before stop
1:Restart
The third part of LED:
0:The wobble freq. is fixed
1:The wobble freq. is changeable.
The fourth part of
LED: Storage
characteristics of
wobble freq.
0:It will not save the running state of
wobble freq. after power off
1:It will save the running state of wobble
freq. after power off
1 1000
F7.1 Preset freq. of wobble freq. 0.0the upper limit freq. 0.01 10.00
F7.2 Waiting time of preset freq. 0.06000.0Sec 0.1 0.0
F7.3 Amplitude of wobble freq. 0.050.0(%) 0.1 10.0
F7.4 Jumping freq. 0.080.0(%) 0.1 10.0
F7.5 Triangular rise time 0.11000.0Sec 0.1 10.0
F7.6 Triangular fall time 0.11000.0Sec 0.1 10.0
F7.7
Preset center freq. of
wobble freq.
0.0the upper limit freq.
0.01 10.0
Wobble freq. running parameter unit
F7.8 Reserved