SUNFAR C300 33
C300 series of non-sensor current vector-control inverter manual
Parameters’
Types
Function Code Name Setting range
Minimum
Setting
Manufacture
Setting
Modify
Limit
F6.16 Copy parameter function 0:Forbid 1:Allow 1 1
F6.17 Manufactory password 0~9999 1 1000
F6.18 User password 0~9999 1 0
Advanced
running
paramete
r unit
F6.19 Reference password 0 ~ 9999 1 ▲
F7.0
Wobble freq.
running mode
The first part of LED (form right to left)
0:Function of wobble freq. is invalid.
1:Function of wobble freq. is valid.
2:Function of wobble freq. is conditional
valid.
The second part of LED: restart mode
0:Restart according to parameters saved
before stop
1:Restart
The third part of LED:
0:The wobble freq. is fixed
1:The wobble freq. is changeable.
The fourth part of
LED: Storage
characteristics of
wobble freq.
0:It will not save the running state of
wobble freq. after power off
1:It will save the running state of wobble
freq. after power off
1 1000 ★
F7.1 Preset freq. of wobble freq. 0.0~the upper limit freq. 0.01 10.00
F7.2 Waiting time of preset freq. 0.0~6000.0Sec 0.1 0.0 ★
F7.3 Amplitude of wobble freq. 0.0~50.0(%) 0.1 10.0
F7.4 Jumping freq. 0.0~80.0(%) 0.1 10.0
F7.5 Triangular rise time 0.1~1000.0Sec 0.1 10.0
F7.6 Triangular fall time 0.1~1000.0Sec 0.1 10.0
F7.7
Preset center freq. of
wobble freq.
0.0~the upper limit freq.
0.01 10.0
Wobble freq. running parameter unit
F7.8 Reserved