SUNFAR C300 37
C300 series of non-sensor current vector-control inverter manual
Parameters’
Types
Function Code Name Setting range
Minimum
Setting
Manufacture
Setting
Modify
Limit
FC.4
Function Protection in
operation
The first part of LED(form right to left):
Under voltage compensation intensity
The second part ofLED:
Over voltage inhibit intensity
The third part of LED:
Over current inhibit intensity
The fourth part ofLED:
Self-adaptingbraking torque adjust
intensity
1 3333
FC.5 Function Action selection
the first part of LED(form right to left):
Cooling fan control
0: Cooling fan run after inverter run.
1: Cooling fan will automatic run when
inverter is power on.
The second part ofLED:
Variable speed control of cooling fan
0:Invalid
1:Valid
Cooling fan always keep the max speed.
The third part of LED:
Voltage over modulation
0:Invalid
1:Valid
The fourth part of LED:Reserved.
1 0010
FC.6 Reserved
FC.7 Reserved
FC.8 Agency password 0 ~ 9999 1 100
FC.9 Rotational speed coefficient 0.10~5.00 0.01 1.00
Special function parameter unit
FC.10
Gain of closed loop of
rotating speed
0.50~1.20 0.01 1.00