Always disconnect the Versa6SDPro
TM
from electrical power supply before
servicing,wiring, or opening internal covers. Risk of electrical shock could
occur whenpanels are opened while the unit is plugged in.
Do not modify the Versa6SDPro
TM
plug in any manner. U.S. installations: Always
plugthe power cord into a properly configured 230-volt Nema L630 outlet only as
shown below in Figure A. International installations: The Versa6SDPro
TM
shall be
hardwired into a disconnect box according to local electrical codes. The
disconnect box needs to be connected to a dedicated 230V/30A circuit. See
Figure B below for reference only.
It is recommended that the Versa6SDPro
TM
unit be used on a dedicated 230V/
30AMP circuit which powers only the Versa6SDPro
TM
, and has no additional
outlets orbranch circuits. If the provided plug does not fit into your outlet, consult
aqualified electrician to evaluate the power outlet, and to safely update wiring if
necessary. All wiring must be in accordance with local and national electrical
standards.
Never disconnect the plug by pulling on the cord. To safely disconnect from the
outlet, grasp the head of the plug firmly, and pull away from the outlet.
Do not overload wall outlets. Overloaded wall outlets, loose or damaged wall
outlets, extension cords, frayed power cords, or damaged or cracked wire
insulation are dangerous! Any of these conditions could result in electric shock or
iii
Figure A: U.S Plug Figure B: International Disconnect