18
NOTE:
The position of the detent adjust screw 5 is as shown in right
figure.
5. Loosen the lock nut(s) 6 while holding the adjust screw(s)
5.
Turn the adjust screw(s) with a hexagon wrench.
Turning the adjust screw clockwise:
detent force will increase
Turning the adjust screw counterclockwise:
detent force will decrease
a: Hex. wrench
NOTE:
Adjustment of detent force for the dual control lever can be
made independently as shown in right figure.
6. To fix the adjustment, tighten the lock nut 6 while holding
the adjust screw.
a: Hex. wrench
7. After the adjustment has been made, reinstall to the original
position the parts that have been removed (upper cover,
grommet, etc.).
SINGLE LEVER CONTROL
DUAL LEVER CONTROL