34
INSTALLATION OF SWITCH PANEL
NOTICE
Install the emergency stop switch panel and main switch panel at an appropriate position on the dashboard.
Installing dimensions are as shown in the figure below.
MAIN SWITCH PANEL ASSEMBLY
INSTALLING HOLE DIMENSIONS:
Make two (2) holes of 52 mm in diameter on the main switch panel assembly as shown in the figure below.
Distance between centers of two (2) holes is 37 mm.
Fix the panel with four (4) screws.
Installing the switch panel in an inappropriate location can result in switch failure or operating
difficulties.
• Do not install the switch in a location where it is likely to be sprayed with water.
Exposure to water can cause failure of the switch.
• Be sure to install the switch on the dashboard in a location that makes it convenient for the
operator to use the switch.
Avoid locating the switch where the operator’s view of the switch is obstructed.
68 (2.68)
53 (2.09)
61.3 (2.4)
88 (3.46)
33 (1.3)
7.5 (0.3)
108 (4.25)
93 (3.66)
Unit: mm (in.)
52 mm (2.04 in.)
52 mm (2.04 in.)
37 mm
(1.45 in.)