64
Cable connecting
NOTE:
• Maximum alternator output generated by a DF350A outboard
motor through the accessory isolator lead is 25 A. In multiple
engine installations (twin & triples) if the accessory isolator
lead wires are connected from each motor to a common auxil-
iary battery, the total alternator charge rate could be 50 A or
75 A respectively.
• As such, it is important to select an appropriate auxiliary bat-
tery charge (current) rate that meets the electrical power con-
sumption of your boats electrical equipment.
NOTE:
• Excessive charge rate may shorten battery life.
• Insufficient charge rate may cause discharge of the battery.
Outboard
motor
Engine operating
battery
12 V 130 AH
Accessory battery
12 V 130 AH
Engine operating
battery
12 V 130 AH
Accessory battery
12 V 130 AH
Engine operating
battery
1 Battery cable +
2 Battery cable -
3 Sub battery cable
4 Isolator lead wire
5 Cable connecting -
terminals of battery
Outboard
motor
Outboard
motor
12 V 130 AH
For single engine For dual engine