18. ELECTRICAL SYSTEM
18-4
Battery
Removal
Loosen 4 screws and remove the battery cover.
Disconnect the negative cable terminal first, then
the positive cable terminal.
Remove the battery from the motorcycle.
Voltage Check
Use the digital voltmeter to check the voltage of
the battery.
Voltage:
Fully charged: 13.0~13.2 V at 20
Undercharged: Below 12.3 V at 20
Charging
Connect the positive terminal (+) of the charger to
the battery positive terminal (+).
Connect the negative terminal (-) of the charger to
the battery negative terminal (-).
Standard Maximum
Charging current 0.9A 4.0A
Charging time 5H 1H
Warning
y Keep flames away while recharging.
y Charging is completely controlled by the
ON/OFF switch on the charger, not by
battery cables.
Caution
y Never rapid charge the battery unless in
emergency.
y Verify the battery is recharged with current
and duration prescribed above.
y Large current and fast time to charge will
render damage to the battery.
When installing the battery, coat the cable terminal with grease.
To this chapter contents
4 screws