13. COOLING SYSTEM
13-6
Check reserve tank
y Remove the front cover, and then remove
reserve tank filler cap.
y Check the liquid level in the reservoir. Add
coolant to proper level if too low.
y Reinstall the reserve tank filler cap.
Caution
The reserve tank liquid level coca too is not high,
after avoids the water temperature elevating, in
the cooling system the refrigerant backflow
floods.
Radiator
Check
Remove the front cover, check for any leakage
from weld seam.
Blow radiator clean using compressed air. If the
radiator is blocked by dirt, use low pressure water
jet to clean it.
Care shall be taken when straightening the sink
fan.
Removal
Coolant leakage
Sets at a vessel underneath the water pump,
dismantles the drain bolt to leak off in the cooling
system refrigerant.
Remove front cover.
Disconnect the couplers for the thermo switch and
fan motor.
Remove coolant inlet pipe.
Loosen the radiator 2 bolts.
Viewing window
Drain bolt
Thermo switch coupler
Coolant inlet pipe
2 bolts