Scanning 2 - 3
High-high beeps Enter another criterion or action, or scan the
Save Rule
bar code.
High-low-high-low beeps Rule saved. Rule entry mode exited.
High-low-low beeps All criteria or actions cleared for current rule, continue entering
rule.
Low beep Delete last saved rule. The current rule is left intact.
Low-high-high beeps All rules have been deleted.
Short low-short high-short low-short high
beeps
Out of host ADF parameter storage space. See
Default
Parameters on page 5-4
.
ADF Programming Error Indications
Low-high-low-high beeps Out of rule memory. Erase some existing rules, then try to save
rule again. (It is not necessary to re-enter the current rule.)
A DS3578 digital scanner was inserted into an STB3478 cradle.
Low-high-low beeps ADF transmit error. Cancel rule entry. Rule entry mode exited
because of an error or the user asked to exit rule entry.
Low-high beeps Entry error, wrong bar code scanned. Re-enter criterion or action.
All previously entered criteria and actions are retained. Criteria or
action list is too long for a rule.
Host Specific
USB Only
Four high beeps The digital scanner did not complete initialization. Wait several
seconds and scan again.
Short high-short low (disconnect)
followed by a short low-short high
(reconnect) beep sequence
1. The digital scanner scanned a USB device type. The digital
scanner must establish communication with the bus before it can
operate at the highest power level.
2. The USB bus may cause power to the digital scanner to cycle
on and off more than once. This is normal and usually happens
when the host PC cold boots.
RS-232 only
High-high-high-low beeps RS-232 receive error.
High beep A <BEL> character is received and Beep on <BEL> is enabled
(Point-to-Point mode only).
Table 2-1