3 - 6 DS3578 With FIPS Digital Scanner Product Reference Guide
IUID Support Supports IUID parsing. The ability to read and separate IUID
fields per application requirements
Typical Working Distance See
Decode Ranges on page 2-8
Print Contrast Minimum 25% minimum reflectance differential, measured at 650 nm.
Motion Tolerances Horizontal Velocity: 5 in. (12.7 cm) per second
Interfaces Supported
Keyboard Wedge, RS-232, USB, IBM 468X/469X,
123Scan
2
User Environment
Operating Temperature -4° to 122° F (-20° to 50° C)
Storage Temperature -40° to 158° F (-40° to 70° C)
Charging Temperature 32° to 104° F (0° to 40° C) nominal, 41° to 95° F (5° to 35° C)
ideal
Humidity 5% to 95% RH (non-condensing)
Ambient Light Immunity
Indoor:
Outdoor:
450 Ft Candles (4,842 Lux)
DS3578-SR/HD/DP: 8,000 ft. Candles (86,000 LUX)
DS3578-ER: 9,000 ft. candles (96,900 LUX)
Durability 6.5 ft (2.0 m) drops to concrete;
5 ft (1.5 m) at -4° F (-20° C)
Table 3-3
Technical Specifications - Cradles
Item
Description
STB3508 and FLB3508 STB3578 and FLB3578
Power Requirements 4.75 - 14.0 VDC
Typical Current Draw
Not Charging: 35 mA @ 5V
45 mA @ 9V
105 mA @ 5V
110 mA @ 9V
Fast Rate Charge: 915 mA @ 5V
660 mA @ 9V
915 mA @ 5V
660 mA @ 9V
Slow Rate Charge: 480 mA @ 5V
345 mA @ 9V
480 mA @ 5V
345 mA @ 9V
Interfaces Supported None Keyboard Wedge, RS-232, USB,
IBM 468X/469X
Operating Temperature -4° to 122° F (-20° to 50° C)
Table 3-2
Technical Specifications - Scanner (Continued)