36
.12
1: batch result over tolerance
.13
1: in motion
.14
0: auto feeding 1: Semi-auto feeding
.15
0: auto dumping 1: Semi-auto Dump
40005
Actual batching data of current material 1(data is kept until next
batching, and cleared when power off.
40006
Actual batching data of current material 2(data is kept until next
batching, and cleared when power off.
40007
Actual batching data of current material 3(data is kept until next
batching, and cleared when power off.
40008
Actual batching data of current material 4(data is kept until next
batching, and cleared when power off.
40028
.0
IN1
.1
IN2
.2
IN3
.3
IN4
.4
OUT1
.5
OUT2
.6
OUT3
.7
OUT4
.8
OUT5
.9
OUT6
.10
OUT7
.11
OUT8
.12
OUT9
.13
OUT10
.14
OUT11
.15
OUT12
Register
address
Bit
Below registers canbe read by 03 and write by 06 code
40009
Tare weight
40010
Target of material 1
40011
Target of material 2
40012
Target of material 3
40013
Target of material 4
40014
Material 1 fast feed stop point to target
40015
Material 2 fast feed stop point to target
40016
Material 3 fast feed stop point to target
40017
Material 4 fast feed stop point to target
40018
Spill to target of material 1
40019
Spill to target of material 2
40020
Spill to target of material 3

Questions and Answers: