39
9.3 command format[F3.1 =4,F3.6 =0]
The send command and response is ASCII format.
The remote host send:
R
E
A
D
CR
LF
The terminal response:
Status
A
Mode
B
C
7-byte weight with dp
Unit
End
S
T
,
N
T
,
+
5
8
0
.
0
k
g
CR
LF
Data field explaination
Data field
explaination
status
ST-data stable
US-data is motion
OL-weight out of range
A
,seperator
mode
NT-net weight
GS-gross weight
B
Each frame send 0 and 1 by turn
C
+/- sign
weight
7 bytes weight string with decimal point.if the string
length is less than 7 bytes the prefix will be filled by
space(0x20)
unit
Kg/g/t
End
CR/LF