Issue 3: Mar 96 TMSL 097-45018-02
Page 49
RETRIEVE ALARMS (Contd)
condtype: For GTI only: (Contd):
GTRCOMM = GTI has timed out waiting for a status message from the
GTR
GTRFAILx = hard failure, where x = 1 through 5 (the numbers 1-5 are
diagnostic codes for field service/engineering use only)
<null> = all condtypes, except those listed for PSM
condtype: For RTRV-ALM-ALL:
<null> = all condtypes
srveff: SA = service-affecting condition
NSA = nonservice-affecting condition
<null> = service-affecting or nonservice-affecting conditions
srveff: For RTRV-ALM-ALL:
<null> = service-affecting or nonservice-affecting conditions
Examples:
RTRV-ALM-T1::MRC-1-4:145::MJ,,NSA;
This example, if E1 is the input, tagged as command 145, retrieves major alarms (if any) from
MRC A, span 4.
This example, if analog is the input, will be denied, and an IDNV error code produced.
COMPLETED RESPONSE
If there are no alarms, the format is:
<sid> <date> <time>
M <ctag> COMPLD
;
Example:
TELECOMSOLUTIONS 96-02-08 15:04:14
M 145 COMPLD
;
If there is at least one alarm to report, the format is:
<sid> <date> <time>
M <ctag> COMPLD
[ "<aid>[,<aiddet>]:<ntfcncde>,<condtype>,<srveff>:
[<conddescr>]"]...
"[<aid>]:<ntfcncde>,<condtype>,<srveff>:
[<conddescr>]"
;

Table of Contents

Other manuals for Symmetricom TimeProvider 500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 500 series and is the answer not in the manual?

Symmetricom TimeProvider 500 series Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 500 series
CategoryData Loggers
LanguageEnglish

Related product manuals