SECTION VII - SUPERVISOR KEY ACCESS
44
If a Compact Flash card is installed, a screen similar to the following will
appear. Use the ‘B’ and ‘C’ keys to scroll through the list of available images
files and hit the ‘A’ key to select.
FLASH: A=SELECT, B=UP, C=DOWN, D=END
fmu2500plus.img
NOTE:
A Compact Flash card must be installed on the main board of the
FuelMaster® in order to use this feature. Otherwise, the following message
will appear:
ERROR – UNABLE TO CHANGE TO DIRECTORY.
SUPERVISOR PREVENTATIVE MAINTENACE (PM) MENU
* SUPERVISOR PREVENTATIVE MAINT. MENU *
* A = DISPLAY, B = UPDATE, C=SET D=EXIT *
This submenu offers the options to display a key’s current preventative
maintenance information and to update this preventative maintenance
information.
PM > DISPLAY
A prompt will request insertion of the ProKee® for which Preventative
Maintenance information should be displayed.
PM > UPDATE
Enter the new Preventative Maintenance information on the FMU keypad. A
prompt will then request insertion of the ProKee® to be updated. This entry is
not checked for accuracy.
PM > SET
This option allows for the supervisor to set a new PM interval for vehicles.