SECTION VII - SUPERVISOR KEY ACCESS
45
SUPERVISOR ODOMETER MENU
* SUPERVISOR CHRONO/ODOMETER MENU *
* A = DISPLAY, B = UPDATE, D = EXIT *
This submenu offers the options of viewing a ProKee®’s
Odometer/Chronometer information as well as the opportunity to update
this information if needed.
ODOM > DISPLAY
A prompt will request insertion of the ProKee® for which
Odometer/Chronometer information should be displayed.
ODOM > UPDATE
Enter the new Odometer/Chronometer information on the FMU keypad. A
prompt will then request insertion of the ProKee® to be updated. This entry is
not checked for accuracy.
SUPERVISOR AIM MENU
AIM SUPERVISOR MENU
1=SET PHT, 2=PROGRAM, 3=RESET, D=EXIT
NOTE:
The FuelMaster® must be configured as an AIM programming unit in order to
access this menu. If it is not, the following message will appear:
** FMU HAS NOT BEEN CONFIGURED **
** FOR AIM PROGRAMMING. **
AIM > SET PHT
Set the current Programming Hose Tag (A-F).
AIM > PROGRAM
This option is used to program an AIM unit provided the programming hose
tag is inserted.