SECTION VIII -ERROR MESSAGES & TROUBLESHOOTING
59
** ERROR WRITING ODOMETER TO PROKEE **
** PLEASE TRY AGAIN **
FMU COULD NOT WRITE ODOMETER/CHRONOMETER BACK TO
KEY
The key was inserted and removed too quickly. It should be inserted and
depressed in for 1 second.
** ERROR WRITING P.M. TO PROKEE! **
** PLEASE TRY AGAIN! **
FMU COULD NOT WRITE P.M. BACK TO KEY
The key was inserted and removed too quickly. It should be inserted and
depressed in for 1 second.
* ODOMETER TOO HIGH! PLEASE TRY AGAIN. *
OR
* ODOMETER TOO LOW! PLEASE TRY AGAIN. *
ODOMETER/CHRONOMETER ENTERED ON THE FMU KEYPAD IS
LOWER OR HIGHER THAN THE PREVIOUS VALUE AND RANGE
CALCULATION
User entry is incorrect
Last fueling vehicle key was not re-inserted when prompted
A WRITE ERROR occurred during the last attempt to update the ProKee®’s
odometer reading
Improper RANGE encoded on key
** TRANSACTION CANCELLED BECAUSE OF **
** OUT-OF-RANGE ODOMETER ENTRIES **
TWO CONSECUTIVE INVALID ODOMETER ENTRIES CAUSED
TRANSACTION CANCELLATION
The BAD ODOM TERMINATION system option is enabled on the system and
the two consecutive odometer entries for this transaction are out of range of
the odometer read from the key and range calculation.
For each odometer too high/ too low message which appears on the LCD