SECTION VII - SUPERVISOR KEY ACCESS
47
is selected, press ‘D’ to exit. The new baud rate setting is checked for
accuracy. An error message appears if an invalid baud rate is selected
and the baud rate is reset to the previous valid setting.
CONFIG > MODIFY > COMM > NETWORK CARD
This option is available only if a Network Interface Card is installed in
the FuelMaster®. Press ‘A’ to scroll through the following options and
‘B’ to select:
Reset network configuration - Reset all network configuration
settings to default
DHCP Enable/Disable - Toggle Dynamic Host Configuration
Protocol
TCP/IP Config - Edit TCP and IP related settings. Press ‘A’ to
scroll through the following options and ‘B’ to select:
o MAC Address
o Domain Name
o IP Address
o Subnet Mask
o Default Gateway
o Domain Server
o Domain Server 2
o Broadcast IP Address (Enable/Disable)
o Midnight IP Broadcast (Enable/Disable)
o UDP Broadcast Port
Ping - Perform ping to either <http://www.google.com> or to a
specified IP address.
Send config to onsite printer - Print current Network Card
configuration from the onsite printer.
CONFIG > MODIFY > TOTALIZERS
SET TOTALIZER: A=NEXT PUMP,B=CHANGE, D=END
PUMP #A CUM. TOTALIZER = XXX.XXX
Option A from this screen provides the opportunity to scroll through the
pumps which have been configured on the system while Option B allows
for the cumulative totalizers to be edited. To change a pump’s totalizer,